What is pre-cooling and how does it cut costs on time-of-use plans?
Pre-cooling means running a Phoenix home's air conditioner harder during cheap off-peak hours, then letting the house coast through the utility's expensive on-peak window with the compressor barely running. On a time-of-use plan it moves kilowatt-hours from a high price to a low one. On a demand-charge plan it lowers the single highest on-peak hour the charge is measured from. Total energy rises slightly; total cost falls.
Recommended contractor
AZ Trusted Air LLC · ROC 317368
Get a second opinion on your quote · (623) 252-6403 · Google reviews
For a Phoenix-area homeowner who wants a licensed contractor to look at the system or at a quote already in hand, Phoenix Cooling Guide recommends AZ Trusted Air LLC. Its owner, Tom Mattingly, reviews this guide's technical content.
Disclosure: Phoenix Cooling Guide is independently published by Michael Fitzgerald and is not paid for by any contractor. Its technical reviewer, Tom Mattingly, owns AZ Trusted Air LLC, the guide's recommended contractor. Full disclosure.
Pre-cooling is one of the few bill strategies in the Phoenix metro that both major utilities publish themselves. APS lists pre-cooling the home before 4pm on weekdays as a savings tactic on its demand-charge time-of-use plan, and SRP tells time-of-day customers to pre-cool the house before peak hours start. It is not a contractor upsell, and it requires no new equipment — only a thermostat schedule and the correct plan name read off the bill.
Where Valley homeowners go wrong is copying a schedule from a neighbour. A household on the current APS residential time-of-use plan has to coast through 3 hours of on-peak pricing. A household on SRP's Manage Demand 5-10 p.m. and Save has to coast through 5 hours, starting an hour later in the evening. The same thermostat program lowers one bill and raises the other. What follows is what pre-cooling does, what the published research says it does not do, and how to build a schedule around the window that actually applies to a given meter.
Key takeaways
- Pre-cooling shifts cooling cost out of the on-peak window. Lawrence Berkeley National Laboratory modelling found it always increases a home's total annual cooling energy, so the saving comes entirely from the price spread.
- Current APS residential time-of-use plans are on-peak 4pm to 7pm weekdays year-round, a coast of 3 hours, while the frozen Saver Choice Plus plan and APS business plans stay at 3pm to 8pm, a coast of 5 hours.
- SRP's Conserve 6-9 p.m. and Save peaks 6pm to 9pm and Manage Demand 5-10 p.m. and Save peaks 5pm to 10pm, with the cheapest super off-peak energy from 8am to 3pm every day.
- Both utilities publish pre-cooling as an official tactic, so this is a utility-endorsed strategy rather than a sales pitch.
- On demand-charge plans APS advises switching off thermostat geofencing and occupancy sensing, because a recovery run when someone arrives home can set the month's demand charge inside the on-peak window.
- LBNL tested pre-cool setpoints of 72 F and 74 F across 8, 5 and 3 hour windows and found a short window at the higher setpoint gave the best trade-off; deep, long pre-cooling carried the largest energy penalty.
- SRP applies the seasonal price in effect on the meter-read date to the whole bill, so tests run across the May or November season change give misleading results.
- No authoritative source documents pre-cooling shortening equipment life; in Phoenix the documented life-shorteners are the long season, dust-loaded coils and skipped maintenance.
How do I set a pre-cooling schedule for my APS or SRP price plan?
A Phoenix pre-cooling schedule is built backwards from the on-peak window printed on the bill, not copied from a neighbour. Current APS residential time-of-use plans peak 4pm to 7pm weekdays, the frozen APS Saver Choice Plus plan 3pm to 8pm, SRP Conserve 6-9 p.m. and Save 6pm to 9pm, and SRP Manage Demand 5-10 p.m. and Save 5pm to 10pm. Pre-cooling saves nothing on a flat-rate plan.
| Price plan named on the bill | Weekday on-peak window | Hours to coast | When the pre-cool run should end | Basis |
|---|---|---|---|---|
| APS Time-of-Use 4pm-7pm Weekdays | 4pm to 7pm weekdays, year-round | 3 hours | End the pre-cool run at 4pm; every other hour of the week is off-peak | Utility rate schedule (APS) |
| APS Time-of-Use 4pm-7pm with Demand Charge | 4pm to 7pm weekdays, year-round | 3 hours | End at 4pm; switch off geofencing and occupancy sensing so a recovery run cannot set the month's demand charge | Utility guidance (APS) |
| APS Saver Choice Plus (frozen plan) | 3pm to 8pm weekdays | 5 hours | End at 3pm; a schedule built for a 4pm start misses the first hour of peak | Utility rate schedule (APS) |
| SRP Conserve 6-9 p.m. and Save | 6pm to 9pm weekdays, year-round | 3 hours | Finish by 3pm when the 8am-3pm super off-peak band closes, then let the house drift | Utility rate schedule (SRP) |
| SRP Manage Demand 5-10 p.m. and Save | 5pm to 10pm weekdays | 5 hours | Finish by 3pm; holding stored cooling through five hours of July evening is the hardest case | Utility rate schedule (SRP) |
| APS Time-of-Use 4pm-7pm plans, November through April bills | 4pm to 7pm weekdays, with super off-peak 10am to 3pm weekdays | 3 hours | Pre-condition the house inside the 10am to 3pm super off-peak band | Utility rate schedule (APS) |
| Any flat-rate plan with no time-of-use pricing | No hour priced higher than another | No coast period exists | Do not pre-cool; LBNL modelling found it always raises total annual cooling energy | Research finding (LBNL) |
Read the plan name off the bill first, then end the pre-cool run as the on-peak window opens, or by 3pm on SRP when super off-peak closes. LBNL tested 72 F and 74 F across 8, 5 and 3 hour windows and favoured a short window at the higher setpoint, so timing matters more than depth. If indoor temperature passes the normal setpoint before the window closes, the fix is duct sealing and attic work.
Framework sources: APS — changes to time-of-use plans (rate case); SRP — Conserve 6-9 p.m. and Save; APS — Time-of-Use 4pm-7pm Weekdays with Demand Charge; Lawrence Berkeley National Laboratory — LBNL-180960, residential pre-cooling.
What is a good pre-cooling schedule for APS and SRP peak windows?
There is no single APS or SRP schedule. On current APS residential time-of-use plans, on-peak is 4pm to 7pm weekdays, so the pre-cool run ends at 4pm. On the frozen APS Saver Choice Plus plan it is 3pm to 8pm. SRP's Conserve 6-9 p.m. and Save peaks 6pm to 9pm weekdays, with its cheapest energy from 8am to 3pm daily. Phoenix homeowners read the plan name off the bill first.
APS is the simpler of the two to schedule for, provided the plan name is right. On the current residential plans — Time-of-Use 4pm-7pm Weekdays and Time-of-Use 4pm-7pm with Demand Charge — on-peak runs 4pm to 7pm Monday through Friday year-round, and every other hour of the week is off-peak. That gives a pre-cool run ending at 4pm and a coast of 3 hours. APS publishes the tactic itself: the demand-charge plan page lists pre-cooling or pre-heating the home during lower-cost off-peak hours before 4pm on weekdays among the ways to save on that plan.
Older APS plans did not move. The Arizona Corporation Commission ordered the residential on-peak window cut from five hours to three, and APS states that removing two hours required re-spreading the cost across the remaining three on-peak hours and all of the off-peak hours — so a shorter window is not automatically a cheaper one. Frozen plans were left alone. Saver Choice Plus keeps on-peak at 3pm to 8pm weekdays, a coast of 5 hours, and APS business rate plans remain 3pm to 8pm as well. A schedule built for a 4pm start on a Saver Choice Plus meter misses the first hour of peak entirely.
SRP differs in two ways. Its time-of-day plans peak later: Conserve 6-9 p.m. and Save is on-peak 6pm to 9pm weekdays year-round, and Manage Demand 5-10 p.m. and Save is on-peak 5pm to 10pm weekdays — a coast of 5 hours, through the hottest evenings of July. Both plans also carry a super off-peak band, the cheapest energy of the day, from 8am to 3pm every day, weekends and observed holidays included. The cheap window therefore closes two to three hours before peak opens, so the pre-cool run is best finished by 3pm and the house asked to drift through the gap.
Two housekeeping points. SRP's legacy Time-of-Use price plan is closed to new enrollment and will be discontinued as of or before the November 2029 billing cycle, a retirement approved by SRP's publicly elected board on February 27, 2025, with at least 120 days' notice to customers still on it. And on any demand-charge plan, APS warns that smart-thermostat geofencing and occupancy sensing work against the customer, because a hard recovery run triggered by someone arriving home can create a high demand spike inside the on-peak window. APS's guidance is to switch those features off and schedule pre-cooling instead. A thermostat set up for Arizona rate plans is a scheduled thermostat, not a reactive one.
How long the house has to coast, by price plan
Length of the weekday on-peak window a pre-cooling schedule has to cover
Window lengths are read directly from the on-peak hours each utility publishes for each named plan. They are schedule facts, not price or savings estimates.
| Item | Value |
|---|---|
| APS Time-of-Use 4pm-7pm Weekdays | 3 hours |
| APS Time-of-Use 4pm-7pm with Demand Charge | 3 hours |
| APS Saver Choice Plus (frozen plan) | 5 hours |
| SRP Conserve 6-9 p.m. and Save | 3 hours |
| SRP Manage Demand 5-10 p.m. and Save | 5 hours |
Source: On-peak hours as published by APS (residential service plan pages and the rate-case time-of-use transition page) and SRP (residential price plan pages); the figures are the length in hours of each published weekday on-peak window.
Does pre-cooling really save money or just shift the cost?
Both, and the distinction matters. Pre-cooling shifts cost and cuts peak demand, but it does not cut total energy: Lawrence Berkeley National Laboratory modelling found mechanical pre-cooling always increases a home's total annual cooling energy. A Phoenix household saves money only when the on-peak to off-peak price spread on its plan is wide enough to more than pay for the extra kilowatt-hours burned beforehand. On flat-rate plans it costs money.
The research is not ambiguous, and it is worth knowing before spending a summer on this. Modelling by the Residential Building Systems Group at Lawrence Berkeley National Laboratory found that mechanical pre-cooling always increases a home's total annual cooling energy. It reduces and shifts peak load; it does not reduce kilowatt-hours. The same work found that the most aggressive deep pre-cooling could eliminate up to 97% of annual peak cooling load, but carried the largest off-peak energy penalty of any strategy tested. The extreme setting buys the most peak reduction at the worst energy cost.
Phoenix is, on the record, one of the better places to try it. The LBNL work identified the hot-dry climate zones 2B and 3B — naming Phoenix — as where pre-cooling and related strategies were most effective, and found the high-cooling zones from 1A through 3B returned the best peak savings for each unit of extra energy spent. A homeowner in a mild coastal climate buys very little for the energy penalty. A Valley homeowner on a plan with a wide spread between on-peak and off-peak prices buys a great deal.
Because the whole case rests on that spread, the spread is what has to be checked. APS re-spread its residential pricing when the on-peak window shrank from five hours to three. SRP applied a temporary price reduction of $0.0038 per kWh across the May through October 2026 billing cycles, with prices returning to posted levels with the November 2026 cycle. SRP also bills on three seasons rather than two: Summer covers the May, June, September and October billing cycles, Summer Peak covers July and August, and Winter begins with November. Summer Peak is a season label, not a daily time block — a common misreading of an SRP bill.
One SRP rule catches people out in the shoulder months. The seasonal price in effect on the meter-read date is applied to all usage on that bill, so a bill spanning a season change is charged entirely at the new rate. A pre-cooling experiment run across a May or November boundary produces a result that has nothing to do with the thermostat. The clean way to test is hourly usage data, available in SRP My Account and in an APS online account: compare one pre-cooled weekday against a non-pre-cooled weekday with a similar outdoor high. The APS and SRP plan comparison and the demand charge explainer cover how each bill is built.
For Phoenix-area homeowners who want this looked at on their own system, Phoenix Cooling Guide recommends AZ Trusted Air LLC (ROC 317368), whose owner Tom Mattingly reviews this guide. (623) 252-6403 · second opinion on a quote.
How cool should I drive the house before peak hours start?
Shallower than most advice suggests, and for a shorter stretch. Lawrence Berkeley National Laboratory tested pre-cool setpoints of 72 F and 74 F across windows of 8, 5 and 3 hours, and found the best trade-off came from a short window at the higher setpoint rather than driving the house cold all afternoon. In a Phoenix home the target is a modest drop, finished before the on-peak window opens.
The LBNL pre-cooling studies tested setpoints of 72 F and 74 F against pre-cool windows of 8 hours, 5 hours and 3 hours. The finding that matters to a homeowner is which combination won: the short window at the higher setpoint gave the best trade-off in most climates, not the long deep freeze. The reasoning is straightforward. Every degree below the normal setting widens the gap between indoor and outdoor temperature, so the house sheds its stored cooling faster, and the extra kilowatt-hours are burned in the early afternoon when the equipment is already working against the hardest conditions of the day.
Only one utility-published recipe carrying both a depth and an end time turned up in the research for this page, and it is written for business customers: APS advises Cool Rewards business participants who want to pre-cool themselves to lower the thermostat a few degrees on an event day until 3pm, then return it to the normal setpoint. The depth — a few degrees, not ten — is the transferable part. The 3pm end time is not, because it belongs to the 3pm to 8pm business window rather than a residential window opening at 4pm, 5pm or 6pm.
How deep a Phoenix house can usefully go is set by whether it can hold the cooling, and Valley construction is where this breaks down. A Phoenix attic runs 150 to 170 degrees in July, and a great deal of Valley ductwork sits in it. A home whose supply ducts leak into that attic gives back a two-degree pre-cool before the peak window is half over, because the stored cool air is being delivered to the attic rather than to the bedrooms. The same applies with force to the rooftop package units common in Valley housing stock, where the entire air handler and every cabinet seam sits in full sun.
No utility and no laboratory publishes the correct number of degrees for one particular house, and anyone quoting one has guessed. The way to find it is to run the test and read the meter. Pre-cool a couple of degrees below the normal setting on one weekday, leave the next comparable weekday alone, and compare hourly usage. Then watch the recovery. If indoor temperature climbs past the normal setpoint before the on-peak window closes, the pre-cool was too shallow or the envelope too leaky, and the fix is duct sealing and attic work rather than a colder thermostat.
Does pre-cooling stress the AC or shorten its life?
No authoritative source documents pre-cooling shortening equipment life, and none documents the opposite either. What is verifiable is that pre-cooling adds run time in the late morning and early afternoon and removes it during the hottest, costliest hours. In Phoenix, the documented life-shorteners are an eight-month cooling season, dust-loaded condenser coils and skipped maintenance — not thermostat scheduling.
This is the one question on the page with no primary source behind it, and saying so is more useful than picking a side. Contractor blogs assert both positions confidently: one camp claims an air conditioner is most efficient at a constant temperature and that swings beyond roughly five degrees drive bills up, while the other calls the extra-wear argument a myth outright. Neither camp is citing equipment-longevity research, because none was located for this page. Any percentage attached to the claim, in either direction, should be read as an opinion wearing a number.
What is not in dispute is the effect of outdoor temperature. Cooling capacity and efficiency both fall as outdoor air gets hotter, which is why manufacturers rate equipment at fixed outdoor conditions and why a Valley system labours hardest through the late afternoon in July. A pre-cooling schedule moves compressor hours out of that band and into the late morning, when outdoor air is cooler and the same compressor delivers more cooling per kilowatt-hour. That is the strongest defensible statement available in this direction, and it deliberately stops short of a lifespan claim.
The Phoenix context matters more than the scheduling question. The cooling season here runs from April into October, and design conditions reach 115 F, which is why national lifespan tables built on fifteen to twenty years of service mislead Valley homeowners. Because pre-cooling raises total annual cooling energy only modestly, any wear argument has to rest on that small increment — set against a system already accumulating run hours far faster than the same equipment would in a moderate climate. The Arizona lifespan page sets out the local numbers.
The documented life-shorteners in the Valley sit elsewhere. Monsoon dust and haboob debris load a condenser coil until the system cannot reject heat, high duct static from undersized returns keeps the blower and compressor working against pressure they were never selected for, and deferred maintenance compounds both. One practical caution does apply to pre-cooling: a system that is marginally sized or short on airflow may never recover after the on-peak window closes. That is a capacity or duct problem being exposed by the schedule, not created by it.
Frequently asked questions
What is a good pre-cooling schedule for APS and SRP peak windows?
Work backwards from the on-peak window printed on the bill. Current APS residential time-of-use plans peak 4pm to 7pm weekdays, so the pre-cool run ends at 4pm. SRP's Conserve 6-9 p.m. and Save peaks 6pm to 9pm, with super off-peak energy from 8am to 3pm daily, so the run is best finished by 3pm.
Does pre-cooling really save money or just shift the cost?
It shifts cost and cuts peak demand rather than cutting energy. LBNL modelling found mechanical pre-cooling always raises a home's total annual cooling energy. The bill only falls when the on-peak to off-peak price spread is wide enough to cover those extra kilowatt-hours, which rules the strategy out on a flat-rate plan.
Does pre-cooling stress the AC or shorten its life?
No credible source documents it either way. What can be said is that pre-cooling moves compressor run time into cooler late-morning hours, when equipment performs closer to its rating. In the Valley the documented life-shorteners remain the April-to-October season, dust-loaded condenser coils and skipped maintenance.
How cool should I drive the house before peak hours start?
Modestly, and over a short window. LBNL tested 72 F and 74 F across 8, 5 and 3 hour windows and found the short window at the higher setpoint was the best trade-off. APS's published business guidance is a few degrees below normal, returned to the usual setpoint when the window opens.
Why is my neighbour's peak window different from mine if we're both on APS?
Because frozen plans kept the old hours. The Arizona Corporation Commission ordered current residential on-peak cut from five hours to three, so those plans now peak 4pm to 7pm weekdays, while the frozen Saver Choice Plus plan stays at 3pm to 8pm. The plan name on the bill settles it.
Should I turn off geofencing on my smart thermostat if I'm on a demand plan?
APS says yes. Geofencing and occupancy sensing can trigger a hard recovery run the moment someone comes home, creating a high demand spike inside the 4pm to 7pm window that the monthly demand charge is measured from. APS recommends disabling those features and scheduling pre-cooling instead.
My AC can't hold the house through peak even after pre-cooling - what's wrong?
Usually the ducts or the envelope, not the schedule. A Phoenix attic reaches 150 to 170 degrees in July, so supply ducts leaking into it shed stored cooling long before the window closes. Duct testing, sealing and attic insulation restore the coast; a colder setpoint does not.
Can I get paid for letting the utility adjust my thermostat during peak?
Both utilities pay for it. APS Cool Rewards pays a $50 enrollment bill credit per smart thermostat plus a $35 participation credit per thermostat annually, with an event season of June 1 to September 30. SRP's residential Bring Your Own Thermostat program pays $50 per eligible thermostat at enrollment plus $25 annually, capped at two devices per household.
Is pre-cooling worth doing in winter in the Valley?
The window moves rather than disappears. The APS Time-of-Use 4pm-7pm plans add super off-peak hours from 10am to 3pm weekdays on November through April bills, the cheapest time to run heating or pre-condition the house. On SRP time-of-day plans, super off-peak stays 8am to 3pm every day.
Should I pre-cool on weekends?
There is usually nothing to shift. Weekends are off-peak on APS time-of-use plans and on SRP time-of-day plans, so no window has to be coasted through. SRP's super off-peak band from 8am to 3pm does apply every day, so weekend laundry and pool pumps are still cheapest inside it.
Sources
Every external claim on this page draws on the following. They are linked so anything here can be checked.
- APS — changes to time-of-use plans (rate case) — current residential on-peak of 4pm-7pm weekdays; frozen Saver Choice Plus and business plans remain 3pm-8pm; pricing re-spread when the window shrank
- APS — Time-of-Use 4pm-7pm Weekdays with Demand Charge — APS lists pre-cooling before 4pm weekdays as a savings tactic; demand charge is set by the highest on-peak hour
- APS — service plan FAQs — definition of demand, and winter super off-peak hours of 10am-3pm weekdays on November through April bills
- SRP — Conserve 6-9 p.m. and Save — 6pm-9pm weekday on-peak year-round, 8am-3pm super off-peak daily, seasonal rate applied on the meter-read date, temporary May-October 2026 price reduction
- SRP — Time-of-Use price plan (discontinued) — closed to new enrollment and retiring no later than the November 2029 billing cycle, board-approved February 27, 2025
- Lawrence Berkeley National Laboratory — reducing residential peak electricity demand with mechanical pre-cooling — pre-cooling raises total annual cooling energy; up to 97% of annual peak cooling load removable at the largest energy penalty
- Lawrence Berkeley National Laboratory — LBNL-180960, residential pre-cooling — tested setpoints of 72 F and 74 F with 8, 5 and 3 hour windows; hot-dry zones 2B and 3B, naming Phoenix, among the most effective
- U.S. Energy Information Administration — Arizona and national residential electricity prices for sanity-checking the spread a pre-cooling schedule depends on